Tom Shelley reports on a development that promises major repercussions for electromagnetic radiation

Rays of hope from active sensors

Huge improvements in medical X-ray and gamma ray imaging are expected to become possible in the near term, thanks to the development of large area, wafer-sized solid state sensor arrays.
The breakthrough comes out of a UK research council-sponsored initiative to develop new kinds of imaging systems – and the medical research fraternity seems to have been first to grasp the opportunities.
X-ray images of items can now be obtained by using phase contrast techniques that show up features in delicate samples that are quite invisible using conventional methods. As a result, detection of the early stages of breast cancer is likely to become easier and more reliable, and many other branches of scientific research greatly assisted, since the fundamental technology works over most of the electromagnetic spectrum.
Known as Multidimensional Integrated Intelligent Imaging (MI-3), the technology has been developed by an 11-member consortium under the leadership of Professor Nigel Allinson at the department of electronic and electrical engineering, University of Sheffield. The project has £4.4million of funding under the Research Council’s Basic Technology programme.
At a recent seminar, Allinson explained that the project involves having arrays of photodiodes produced in CMOS. This allows electronic circuitry to be placed alongside the sensing elements, so that they become active pixels. This is the alternative solid state way of capturing solid state images to CCDs – the technology used in most digital cameras – although active pixel arrays are now the most common devices used in mobile phone cameras.
With on-chip processing, it becomes possible to boost sensitivity, resolve images at finer scales than the sizes of individual pixels and undertake various kinds of image enhancement. The MI-3 sensors are intended to cover a spectral range that extends from ionising particles to infrared.
“Using the on-chip intelligence down to pixel level, we can read out just the bits of interest – when they are of interest,” states Allinson.
He confirms that the sensors are ultimately intended to observe events occurring over timescales ranging from femtoseconds to hours.
The programme has already produced a number of usable devices. The first, called StarTracker, is based on a pre-existing design developed by the Rutherford Appleton Laboratory with 525 x 525 pixels, each 25 microns square. This has led on to another version called the Vanilla Sensor, which has 512 x 512 pixels, each 25 microns square. Fill factor is 85% and the device can be read to 12-bits resolution. Eureka was shown an image of a mouse brain derived from radiation from tritium. It took 28 days to obtain using conventional photographic emulsion, but Kevin Wells and Jorge Cabello at the University of Surrey took only a day and a half to produce using a back-thinned Vanilla sensor.
This has led on to a large area sensor with 1400 x 1400, 40 micron pixels, giving an active area of 58 x 58mm. Meanwhile Dr Renato Turchetta from the Rutherford Appleton Laboratory describes future wafer scale integrated sensors as a possibility.
One of the big attractions of having a large area image sensor is that it can be made to work with X-rays, which are extremely difficult to focus. According to Professor Robert Speller, from the department of medical physics and bioengineering at University College, London: “When using radiation to treat cancers, one wants to deliver a uniform dose, while saving the surrounding tissues.”
The tumour may be moving as the patient breathes, he points out, so it would be desirable to be able to image the X-rays coming through the patient in real time, so that they could be targeted on the tumour and nowhere else.
He says it is also possible to image the distribution of single gamma ray photon emitters, such as radioactive technetium in tissue, by using a Vanilla sensor with caesium iodide needles deposited in holes in front of the sensing layer. The caesium iodide then scintillates when it is struck by the gamma rays.
Due to the extreme sensitivity of the sensors, it is possible to use them to study tissue, or anything else being X-rayed, in two novel ways. The first of these is Tissue Diffraction Imaging: looking at diffracted X-rays, instead of those that have passed straight through. “In many instances,” says Speller, “the disease cannot be seen [using conventional technology]. What you see in a conventional mammographic image is rarely the tumour.” But by using a diffraction method, it is very clear there is distinction, he adds. His team has been conducting experiments using a ‘Pink beam’ and Vanilla sensors.
Another technique the team has been working with is X-ray phase contrast imaging – or XPCi. By this method, a conventional X-ray source with ‘Coded apertures’ can reveal X-ray images of the internals of a common wasp that are quite impossible to see in a conventional X-ray image.
“This is proof of concept,” says team member Dr Alessandro Olivo. “We have demonstrated it is feasible. We have built the setup, and compared simulation and experiment. What we need now is a good grant to build a full-sized prototype. If you use it to look at nylon fibre 300 microns in diameter, you don’t even see it in a normal X-ray image – the contrast is less than one per cent – but phase effects give a contrast of 24 per cent.” The coded apertures, he says, are arrays of L-shaped slots, 20 microns in each direction.
Speller also describes another novel technique, dual energy perfusion mammography – “for the early stages of breast cancer where you can’t see anything” – to look at the uptake of iodine. So far, this has only been tried on experimental samples, not on humans, but appears to work well. “We might be able to give medicine a new science,” he concludes.

Pointers
* CMOS active pixel imaging sensors have been developed of extreme sensitivity, sufficiently radiation hard to be usable with X-rays

* Because of their extreme sensitivity and large areas, they can be used with novel X-ray techniques that are not practicable with conventional technologies

* The most promising application areas are in medical applications, particularly the improved early diagnosis and treatment of cancer

http://mi3.shef.ac.uk

 
Author
Tom Shelley
 
 
This material is protected by Findlay Media copyright 2010.
See Terms and Conditions.
One-off usage is permitted but bulk copying is not.
For multiple copies contact the sales team.
 
Bookmark this article using:
 
Del.icio.us digg reddit Facebook StumbleUpon
 
 
Your comments / feedback
Do you have any comments or feedback on this article? Please contact us by filling in the form below.
NameHide name
Your Email Address
Comments
Send
We may edit your comments and not all entries will be published.
Terms and Conditions

To comment on news stories or blogs you need to complete our 60 second registration process. Once completed this then allows you to download any and all white papers, register for e-zines and access our detailed supplier directory for FREE.

If you are all ready a registered user then enter your e-mail address and login.

You will need to have logged in prior to entering your comments in the boxes provided.

Please enter your email address to login and gain free access to this site.
 
If you are using this site for the first time registration is quick and completely free.
 
Register Now - Register Now


Email Address :  

Remember Me: - If this box is ticked you will be automatically logged in when you return.

Important: To protect your privacy, do not select 'Remember Me' if other users have access to the computer you are using.

 
Related Companies
University of Sheffield
 
 
Related News
Sensor provides volcanic data
 
£1.1million investment in quantum nanotechnology for touch sensors
 
Ultra wins £20million contract to supply nuclear reactor sensors
 
IFM announces newest range of tiny photocells
 
SICK extends bar code benefits
 
 
Related Technology
Magnetised shafts measure torque by field
 
Shows focus on the future
 
Ultrasonic flowmeter appeals to new markets
 
Micro sensors take on big markets
 
Pressure sensing staff senses oil and water in separators
 
 
Related Products
Cable extension position sensors
 
Pressure Transmitter
 
High flows in miniature packages
 
Low cost measurement of high temperature applications
 
Rotary magnetic encoders for harsh environments
 
 
Related Events
Advanced Manufacturing UK