Should I use filters or active front-end drives to help reduce harmonics?
06/07/2010 Email to a friend   Comment on this article
Every consumer has an allowance for the total harmonic currents that they can pass back to the supply, which are defined in the Energy Networks Association Engineering recommendation G5/4-1.

There are basically two methods of installing a drive and achieving low network harmonics, either use a standard diode rectifier, and apply mitigation and filtering techniques, or avoid harmonics at the outset.



Should I use filters or active front end drives to help reduce harmonicsEvery consumer has an allowance for the total harmonic currents that they can pass back to the supply, which are defined in the Energy Networks Association Engineering recommendation G5/4-1.

There are basically two methods of installing a drive and achieving low network harmonics, either use a standard diode rectifier, and apply mitigation and filtering techniques, or avoid harmonics at the outset.

An active front end drive (AFE) by its construction produces extremely low levels of harmonics. It is well known that the harmonics passed by a modern inverter to the motor under control are very low, as evidenced by the minimal de-rating needed, therefore an AFE comprises an inverter, but used as a rectifier, with a low pass filter.

Most frequency converters use diode rectifiers which create high levels of harmonics. These have to be cleaned up after they have been created, while an AFE will go into battle on your behalf by actively modulating the voltage and frequency to reduce harmonic overtones. When looking at filtering, there are active and passive types. Active filters compensate harmonics by generating the same harmonic components in the opposite phase.

Harmonics occur when non-linear loads are connected to the power supply, and these may include electronic soft starters for motors, variable speed drives, computers, TV, radio and other electronic devices, electronic lighting, welding supplies and uninterruptible power supplies.

A plain diode rectifier will generate relatively high levels of harmonics, while reputable manufacturers may mitigate the levels of harmonic by fitting passive filtering. If this is inadequate, then one of the active approaches will be worth considering.

When choosing between AFEs and an active filter, there are a number of factors to bear in mind. Firstly, the active filter will have substantial losses that need to be taken into account. There must also be an allowance for the standing distortion of the network. This may well be out of phase with the new harmonic load and the use of a filter can result in a poorer power quality.

It will also be necessary to consider the need for regeneration or raised DC levels. In addition, the choice between AFEs and an external active filter is dependent on the number of drives installed and their sizes.

In general, a single drive up to 37kW meeting EN 61000-3-12 will not need any additional filtering on a 400 V network. A large number of independent small drives are best filtered by an active filter, while a few larger drives will in most cases be best suited for AFE solutions.

In all work with harmonic mitigation, it is important to remember that it is not only the drives on a system that need to be considered. The network also has a huge influence and a skilled pre-installation survey and evaluation can save enormous costs.

www.abb.co.uk/energy

Contact for more information

 
Author
ABB Ltd
 
 
This material is protected by Findlay Media copyright 2012.
See Terms and Conditions.
One-off usage is permitted but bulk copying is not.
For multiple copies contact the sales team.
 
Bookmark this article using:
 
Del.icio.us digg reddit Facebook StumbleUpon
 
 
Your comments / feedback
Do you have any comments or feedback on this article? Please contact us by filling in the form below.
NameHide name
Your Email Address
Comments
Send
Your comments/feedback may be edited prior to publishing. Not all entries will be published.
Terms and Conditions

To comment on news stories or blogs you need to complete our 60 second registration process. Once completed this then allows you to download any and all white papers, register for e-zines and access our detailed supplier directory for FREE.

If you are all ready a registered user then enter your e-mail address and login.

You will need to have logged in prior to entering your comments in the boxes provided.

Please enter your email address to login and gain free access to this site.
 
If you are using this site for the first time registration is quick and completely free.
 
Register Now - Register Now


Email Address :  

Remember Me: - If this box is ticked you will be automatically logged in when you return.

Important: To protect your privacy, do not select 'Remember Me' if other users have access to the computer you are using.

View Privacy Policy
 
Related Companies
ABB Ltd
 
 
Related News
Schaeffler plant produces one millionth ball screw drive
 
 
Related Products
Hydrostatic linear guides dampen loads in high speed machining applications
 
Techdrives announces products for linear motion
 
 
Related Technology Spotlight
Miniature internal gear pumps perfect for OEM applications
 
Conquer small spaces with PICCO
 
ABB launches BlackBerry App
 
IPSOL's solar panel centre of excellence uses MiniTec Motion System
 
NSK’s free pocket - sized publication is perfect designers guide to best in linear motion equipment