Novel sensor finds its level
16/03/2011 Email to a friend   Comment on this article
How an enquiry for one technology led to the invention and development of another. Paul Fanning reports.

Novel sensor finds its levelA general purpose level sensor that eliminates the unwanted effects of Hall sensors has come about because of a meeting brought about by an article in Eureka.

Following an article published in last year about the Optical Level Sensor (Eureka, May 2010), Rotech Ltd contacted Peter Frank of Product Innovation regarding 'Keg Line Monitoring' to measure liquid level, temperature and pressure during the sterilisation process of beer kegs.

Rotech had been using a very thin long PCB loaded on both sides with reed switches. A magnetic float outside the tube containing this PCB finished the job. However, the company was getting faulty boards due to the glass of one or more reed switches breaking.

Solving these problems became the vital task and the key to success. Initially, as temperature requirements would be in excess of the specification for the optical components in the Optical Sensor, the two companies considered replacing the reed switches with high-temperature versions of the Hall Effect transistors. A full length PCB containing a row of Hall Effect transistors that was narrow enough to fit in the existing narrow stainless tube that houses the reed switch chain was built.

However, the Halls and reed switches are not directly interchangeable and the old system relied on the fact that a reed was either open circuit or short circuit. This meant that getting an output voltage proportional to the height of the magnetic float was simplicity itself. But Halls have two undesirable features for this application: when they are switched on by a magnet they are conducting, but not short circuit, and when they are switched off there can be some current leakage.

Both of these features will significantly affect any output calculation. After some thought , a control PCB was designed that takes a series of different measurements, rather than the one necessary when using the reed device - one measurement immediately after the other.

By using several ingenious mathematical steps it is now possible to eliminate both of the Halls' unwanted features. This meant that the basic long PCB is now attached to the control PCB making the measurements and then calculates the liquid level and outputs this either as a voltage or as a 4 – 20mA signal.

All of this is accomplished in under 500uS. For the keg application, the device is then put into power saving mode so that battery life is extended to several years. A new measurement is taken every 0.5 seconds. "We take about five different measurements of different parts of the system and combine it with a couple of equations that allows us to eliminate these unwanted features," says Peter Frank. "Another nice feature," says Frank, "is that the PCB that goes down the front of the tube is 5mm wide by 300mm long – very narrow.

However, you can join them together in such a way that you can have them pretty much any length you like and the electronics will just recognise that – it will measure the entire length and work in proportion to that. This makes it very, very flexible in terms of customer requirement." Franks claims that the technology that could have much wider, more general applications, saying: "We have developed a high resolution, wide temperature range, high pressure, variable length sensor that needed a very narrow aperture in any tank in order to be installed and used.

So in addition to the specialised version for the keg, we are now launching a general purpose level sensor for use in many applications." Both products will be on show at the MTEC exhibition in Birmingham this April.
 
Author
Paul Fanning
 
 
Supporting Information
http://www.productinnovation.com
http://www.rotechkeg.co.uk
 
This material is protected by Findlay Media copyright 2012.
See Terms and Conditions.
One-off usage is permitted but bulk copying is not.
For multiple copies contact the sales team.
 
Bookmark this article using:
 
Del.icio.us digg reddit Facebook StumbleUpon
 
 
Your comments / feedback
 
Added: 14/06/2011 | 15:23
 
I wonder if they ever tried an encapsulated reed switch. They are much more rugged and might have solved their problem without all that engineering effort.
 
Posted by:
 
Report Abuse
Do you have any comments or feedback on this article? Please contact us by filling in the form below.
NameHide name
Your Email Address
Comments
Send
Your comments/feedback may be edited prior to publishing. Not all entries will be published.
Terms and Conditions

To comment on news stories or blogs you need to complete our 60 second registration process. Once completed this then allows you to download any and all white papers, register for e-zines and access our detailed supplier directory for FREE.

If you are all ready a registered user then enter your e-mail address and login.

You will need to have logged in prior to entering your comments in the boxes provided.

Please enter your email address to login and gain free access to this site.
 
If you are using this site for the first time registration is quick and completely free.
 
Register Now - Register Now


Email Address :  

Remember Me: - If this box is ticked you will be automatically logged in when you return.

Important: To protect your privacy, do not select 'Remember Me' if other users have access to the computer you are using.

View Privacy Policy
 
Related Companies
Product Innovation Ltd
 
Rotech Engineering Ltd
 
 
Related News
Micro-Epsilon launches ultra small position sensor for miniature hydraulic cylinders
 
Millimetre-wave radar technology could reduce road traffic accidents
 
Blind spot technology should be mandatory, says IMechE
 
Oscillating gel could give robots ability to ‘feel’
 
Pressure transmitter targets pump and compressor applications
 
 
Related Technology
Sensing technology takes the lead: Drives & Controls 2012
 
Monitoring technology takes the strain
 
Acoustic emission sensor enables early stage fault detection
 
Crash avoidance technologies get active
 
LED glasses assist visually impaired
 
 
Related Products
Evaluation kit allows for simple testing of differential pressure sensors
 
 
Related Events
SENSORS + SYSTEMS 2012
 
 
Related Technology Spotlight
Micro motion system operates directly from 3VDC battery
 
 
Related Whitepapers
Load Cells – An Overview of their Design and Application
 
Torque Sensors – An Overview of their Design and Application