Tom Shelley reports on an easy to use device for connecting and disconnecting sensing loops to high pressure fluid lines

Making a connection

A connection system developed for the oil and gas industry is finding use across a range of high pressure fluid systems.

PhastFit can quickly connect and disconnect differential pressure transmitters across orifice plates in high pressure process lines. It forms an essential part of Parker Instrumentation's Close Coupled Instrument Mounting Solution (CCIMS).

"The costs of mounting differential pressure transmitters has stayed much the same for decades and are unquestioned by plant owners," said Brian Rice, market development manager of Parker. "We have worked with transmitter manufacturers and users to develop this concept."

It replaces what are usually hand crafted assemblies of 20 or more items - pieces of tubing, joints, valve components and brackets that can take anything from one to three man days to make up. Parker says that the CCIMS can be installed in less than half an hour - at a pre-launch demonstration a non-expert took eight minutes - and disconnections and instrument swaps can be made in only a few seconds. It also shortens the paths between pipe and instrument, which improves response and reduces opportunities for blockages. By reducing the number of joints, it cuts the opportunity for leakage.

The system is made up of two main parts: a pipe interface module with isolation valves, which connects to holes drilled in flanges on each side of the orifice plate; and an instrument mounting module. The pipe interface module includes one ball and one sleeve connector to accommodate various types of misalignment problems associated with the flanges. But the clever part is the interface with the instrument mounting module. Disconnection requires use of a special tool that cannot be inserted unless both isolation valves are closed. Once the instrument mounting module has been removed, the valves cannot be opened. An emerging spigot on the pipe interface module must be pressed down by the presence of the instrument mounting module in order for the valves to open. When the instrumentation module is removed, it is also possible to padlock the spigot in the extended position to make doubly sure the valves are not opened.

When re-attaching the instrument mounting module, the tool allows the seals to be compressed without having to apply large amounts of force to the instrument mounting module. The shape at the end of the tool cannot be imitated using screwdrivers or other pieces of metal, which prevents module removal by unauthorised people.

"CCIMS allows the industry to re-engineer instrument mounting practice, to save cost and enhance performance," said Rice.


Parker CCIMS system

Pointers

* Pipe interface module has ball and sleeve connections to accommodate flange misalignment

* The instrument mounting module is attached by a click and lock mechanism using a special tool - and can only be done with the isolation valves closed. These remain locked in the closed position after removal

* Installation time for the whole system is typically less than half an hour. Instrumentation mounting modules can be removed and replaced in a few seconds


 
Author
Tom Shelley
 
 
Download Articles
 
PhastFitLarge.jpg
 
 
This material is protected by Findlay Media copyright 2012.
See Terms and Conditions.
One-off usage is permitted but bulk copying is not.
For multiple copies contact the sales team.
 
Bookmark this article using:
 
Del.icio.us digg reddit Facebook StumbleUpon
 
 
Your comments / feedback
Do you have any comments or feedback on this article? Please contact us by filling in the form below.
NameHide name
Your Email Address
Comments
Send
Your comments/feedback may be edited prior to publishing. Not all entries will be published.
Terms and Conditions

To comment on news stories or blogs you need to complete our 60 second registration process. Once completed this then allows you to download any and all white papers, register for e-zines and access our detailed supplier directory for FREE.

If you are all ready a registered user then enter your e-mail address and login.

You will need to have logged in prior to entering your comments in the boxes provided.

Please enter your email address to login and gain free access to this site.
 
If you are using this site for the first time registration is quick and completely free.
 
Register Now - Register Now


Email Address :  

Remember Me: - If this box is ticked you will be automatically logged in when you return.

Important: To protect your privacy, do not select 'Remember Me' if other users have access to the computer you are using.

View Privacy Policy
 
Related Companies
Parker Hannifin Ltd
 
 
Related News
Guide explains quick high pressure tube connectors
 
OpenHydro deploys 1MW commercial tidal turbine in the Bay of Fundy
 
Sine wave disk pumps delicate objects
 
Super quiet hydraulic pump developed for electric vehicles
 
Drive saves 70% energy in hydraulic system
 
 
Related Technology
Sponsored story: Building a winning strategy
 
Hydraulic power unfolds for the big view
 
Shows spotlight clean, efficient power
 
Compact actuators bring safe landings
 
Challenging conventional views
 
 
Related Technology Spotlight
Parker commercialises hydraulic hybrid system
 
Hydraulic gearless transmissions for large wind turbines
 
 
Related Videos
Recover Energy - Reduce Emissions
 
 
Downloads
PhastFitLarge.jpg